产品展示

Product Center

current position: Home > Product Center > Electromagnetic flowmeter

contact usContact Us

YUYAO YINHUAN FLOWMETER CO.,LTD

Tel: 0574-62689077 62689099

Fax: 0574-62689088

After-sales phone:0574-62689095 13605848286

E-mail: sales1@yinhuanchina.com

Website: http://www.yinhuanchina.com 

Add:No.1 Rainbow Road, Yuyao City, Zhejiang Province


Intelligent electromagnetic flowmeter

Electromagnetic flowmeter inserted into the integrated type (without valve) ZE intelligent converter

  • Intelligent electromagnetic flowmeter
  • Category:Electromagnetic flowmeter
  • Browse number:
  • QR code:
  • Release time:2022-07-11 17:22:48
  • Product description
  • Product parameters

Overview.


LD series electromagnetic flowmeter is composed of two parts: sensor and converter. Belongs to the velocity flow meter, it is based on Faraday's law of electromagnetic induction work, used to measure the conductivity greater than 5uS/cm conductive liquid volume flow, is an inductive instrument for measuring the volume flow of conductive media. In addition to measuring the volume flow of general conductive liquids, it can also be used to measure the volume flow of strong acids, strong alkalis and other strong corrosive liquids and mud, slurry, pulp and other uniform liquid-solid two-phase suspended liquids. Widely used in petroleum, chemical, metallurgy, light textile, paper, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, river dredging and other fields of flow measurement.


◆Product implementation standard: JB/T9248-2015 (industry standard)


◆General standard of flange: GB/T9119-2010 (national standard)


                         GB/T9115.1-2010 (national standard with neck flange ≥ DN700mm)


◆Type approval certificate: 2009F384-33 2005F271-33 2007F148-33


Working principle.


According to Faraday electromagnetic induction principle, a pair of detecting electrodes are installed on the wall of the pipe perpendicular to the axis of the measuring tube and the magnetic force line, when the conductive liquid moves along the axis of the measuring tube, the conductive liquid cuts the magnetic force line to produce the induced potential, this induced potential is detected by the two detecting electrodes, the value size is proportional to the flow as


E = KBVD formula: E - induced potential: D - electrode spacing; (measuring tube diameter) B - magnetic induction strength: V - the average flow rate of conductive liquid; K - with the magnetic field distribution and axial length of the relevant coefficient.


The sensor takes the induced potential E as the flow signal, transmits it to the converter, and after amplification, conversion filter and a series of digital processing, displays the instantaneous flow rate and the accumulated flow rate by dot matrix LCD with backlight. The converter has 4~20mA output, upper and lower limit alarm output and frequency/pulse output, and is equipped with RS-485 and other communication interfaces, Hart protocol.

Features.


1. No flow blocking parts in the measuring tube, the pressure loss is zero, not easy to block.


2. As long as the reasonable choice of electrode and lining materials, you can achieve the requirements of corrosion resistance, wear resistance, temperature resistance.


3. The measurement result is basically independent of the physical parameters such as pressure, temperature, density, viscosity and conductivity of the liquid (not less than the minimum conductivity), and is not affected by the environment, so the measurement accuracy is high, stable and reliable.


4. Using modern analog signal conversion technology and high-performance super large-scale integrated chip, the signal is isolated, filtered, amplified and digitally processed. Accurate display of measurement results.


5. Automatic monitoring and correction of parameters affecting the measurement results, such as zero drift correction, and the setting and correction of segmented flow coefficients for the full range, thus expanding the measurement range, improving the degree of intelligence and measurement accuracy, and greatly improving the stability performance.


6. With the measured value of power failure protection and over-range alarm function, the flow direction of the fluid in the sensor can be set, so the sensor installation is not limited by the direction of liquid flow, and can achieve two-way flow measurement.


7. With backlight dot matrix double-row flow display, while displaying the instantaneous flow, cumulative flow, and can display the working status, parameters, measurement units, etc.


8. electromagnetic flowmeter range wide (maximum flow / minimum flow), the normal range of 20:1, generally 30:1 or greater.


9. Instrument configuration with a variety of output functions, can be used with computers, unit combination instrumentation, can complete the requirements of printing, communication and networking.







进口面板式流量计除特别规格外,高度均为250mm。对接法兰采用GB/T9119.8~10规范,也可依据客户特别规定订制。lz-50金属管流量计是怎样的?规范型LZ系列lz-50金属管流量计由一个丈量曹和一个就地指示仪组成。

lz-50金属管流量计就地指示仪还可以选择安装额外的电气部件,适用于液态和气体的丈量。金属浮子流量计适合于较低雷诺数,采用黏度失灵形状的浮子,流通环隙处雷诺数只需超过40或500,雷诺数改变流量系数即维持常量,亦即液体黏度改变不影响流量系数。这数值远小于规范填料等节约差压式表面最少雷诺数104-105的要求。大部分金属浮子流量计没有上游直管段要求,或者说对上游直管段要求不高。

Tags

Recently Viewed:

Related products

news.related_news

Contact details

Tel: +86 574 62689077 62689099

Zip code: 315400

Fax: +86 574 62689088

E-mail: sales1@yinhuanchina.com

Address:No.1, Rainbow Road, Yuyao City, Zhejiang Province


Swipe to contact us

Copyright © YUYAO YINHUAN FLOWMETER CO.,LTD All rights reserved record number:浙ICP备15026597号-1 Mainly engaged inMetal tube float flowmeter,metal float flowmeter,glass float flowmeter, Welcome to inquire! Technical Support: 华企立方